Medical Equipment Dynamics - http://medicalequipmentdynamics.com
North American Drager Narkomed 2C Anesthesia Machine
http://medicalequipmentdynamics.com/articles/23/1/North-American-Drager-Narkomed-2C-Anesthesia-Machine/Page1.html
By Equipment Department
Published on 07/26/2008
 
Drager Narkomed 2C Anesthesia Machine
The North American Drager Narkomed 2C is the first mid-range anesthesia system to provide a fully adjustable remote display that presents real-time numeric and patient waveform information, centralized alarm messages and configurability to various display formats. The Drager Narkomed 2C is available used and refurbished.

North American Drager Narkomed 2C Anesthesia Machine

Drager Narkomed 2C Anesthesia Machine
The North American Drager Narkomed 2C is the first mid-range anesthesia system to provide a fully adjustable remote display that presents real-time numeric and patient waveform information, centralized alarm messages and configurability to various display formats.

Holds up to 3 vaporizers

Remote Display
The fully adjustable remote display minimizes clinician strain and improves focus by strategically positioning vital information and centralized alarm messages near the patient's head. The cockpit architecture allows the anesthetist to consistently focus on the patient.
AV-2+ Ventilator
The AV-2+ ventilator is a volume preset, time cycled and pressure limited anesthesia ventilator. It is equipped with electronic timing, pneumatic circuitry and independent controls for frequency, inspiratory to expiratory ratio, inspiratory flow rate, tidal volume, and inspiratory pressure limit. The unit is capable of inverse I:E ratios with a built-in safety mechanism and can be used in a wide range of patient conditions.
Third Party Monitor Interface
Third-Party patient monitor interface protocols are available for communication with NAD Vitalert, Hewlett-Packard, SpaceLabs, Marquette, Datex and other third party monitors.
Absorber
The Narkomed-2C absorber assembly consists of large dual canisters for extended operation between absorbent changes. The systems ceramic inspiratory and expiratory valves resist warp or wear and enhance performance and reliability.
Scavenger System
Waste gas scavenging is accomplished with either an open or a closed scavenging system. In the opensystem neither positive or negative pressure can build up since the patient breathing systems relief ports are open to the atmosphere. The closed system uses spring loaded valves for positive and negative pressure relief.

MED buys and sells used and refurbished (rebuilt) Drager Narkomed 2C anesthesia machines.